Media Conversion, Switching and Data Networking by Transition Networks
search
Contact Tech Support
Downloads
Help Files
Test Partner Program
Product Change Notification
Warranty



CETTF100
This document describes the following Point System topics:

Focal Point - CETTF100 10Mbps Ethernet TX-FL Media Converter


CETTF100 SNMP MIB Variables

The following manageable features are available for the CETTF100:
  • BiaIndex - (Integer, read only) "Burned In Address." This is the serial number of the cabinet into which this CETTF100 is installed.
  • SlotIndex - (Integer, read only) The cabinet slot into which this CETTF100 is installed.
  • Groups - (String, read/write) This is the Device Group String for this CETTF100. For more information on Device Group Strings, see the help for Configuration Management.
  • MRevision - (String, read only) This is the marketing revision level of the device. It is the last three digits of the part number.
  • CfgMatch - (Integer, read only) This value indicates whether or not this particular CETTF100 is selected to receive configuration changes. For more information, see the help for Configuration Management.
  • SerialNumber - (Integer, read only) The serial number for this CETTF100
  • ConnA, ConnB - (Integer, read only) The styles of the connectors installed in this device during manufacturing. ConnA is the Fiber interface, and ConnB is the Copper interface
  • TPLink, FiberLink - (Integer, read only) The Ethernet link state for each of the two media connectors.
  • Fault - (Integer, read only) The value of this variable is yes(1) when either TPLink or FiberLink has the value linkDown(2).
  • TPActivity, FiberActivity - (Integer, read only) Network traffic activity indicators for the two interfaces.
  • AutoCross - (Integer, read/write) Enable/Disable control for automatic Ethernet TX/RX pair correction.
  • LinkPassThrough - (Integer, read/write) Enable/Disable control for the Link Alert feature. When Link Alert is enabled, a loss of link on one interface causes the CETTF100 to drop link on the opposite interface so that the attached equipment can detect the fault.
  • ConfigMode - (Integer, read only) The CETTF100 has a hardware switch block that can be used to set AutoCross and LinkPassThrough, and disallow software changes to these values. The ConfigMode variable shows the state of the switch - i.e. it indicates whether or not Software changes are locked out.
  • Enabled - (Integer, read/write) Traffic through this CETTF100 can be disabled via this control.